Showing posts with label flow meter. Show all posts
Showing posts with label flow meter. Show all posts

Orange Research Pressure & Flow Instrument Catalog

Orange Research is a leading manufacturer of rugged and reliable differential pressure gauges and flow meters. They manufacture a wide line of standard models and invite custom applications. 

Orange Research Products include:

  • Differential Pressure Gauges
  • Differential Pressure Transmitters 
  • Differential Pressure Switches
  • Flow Meters
  • Fixed Set-Point Flow Switches
  • Flow Transmitters

YOU CAN DOWNLOAD THE ORANGE RESEARCH PRODUCT CATALOG FROM THIS ADVANCE INSTRUMENTS WEB PAGE.

For additional information, call Advance Instruments at (888) 388-6446 or visit https://advanceinstruments.com.

PVC Flow Meters for Water and Corrosive Applications

PVC Flow MetersPolyvinyl chloride (PVC) is the world's third-most widely produced synthetic plastic polymer and is chemically resistant to acids, salts, bases, fats, and alcohols.

Orange Research manufactures a line of PVC flow meters and PVC switches for water and corrosive liquids applications with wetted parts of PVC and Teflon. They’re perfect for difficult environments where aluminum, stainless steel or brass is not appropriate.

Their models 2221 and 2321 variable area PVC flow meters handle flow ranges from 0-1 to 0-10 GPM. The PVC bodies handle up to 200 psi pressures. Alternatively, metal pressure bodies with PVC and Teflon wetted parts are available and can handle up to 3000 psi line pressures.

These flow meters also include dials made from durable ABS plastic and offer switches (to alert users of alarm conditions) as a standard option. Transmitters are also available upon request. Accuracy is 2% F.S. and each unit is calibrated to NIST standards.

For more information, contact Advance Instruments. Call them at (888) 388-6446 or visit their Orange Research website page here.

Measuring Industrial Effluent Flow in the Presence of Solids, Fibers, and High Turbidity

Measuring Industrial Effluent Flow
LaserFlow Installation
A manufacturer of high-quality staple fiber and caustic soda treats approximately 3,500,000 gallons of waste water per day from three (3) production units. The effluent from each of these production units varies. In order to optimize the treatment, accurate flow information from each unit is important. Wastewater from two of the production units is clear and without any solid particles; therefore, it can be easily pumped and measured with a closed pipe flow meter.

To reduce energy costs resulting from pumping, the effluent from the third production unit is sent to the treatment plant via gravity feed. The channel is 4.3 feet wide and 5.9 feet high. Therefore, the waste stream must be metered using an open channel method.

LaserFlow
LaserFlow Installation
(looking downward)
Popular flow metering technologies and methodologies presented various problems and challenges as detailed in the table below:

Possibility 1 - Weir with level measurement. Problem: Weirs frequently clog with solids con-tent and require periodic cleaning to get accurate readings. This requires costly plant shutdowns.

Possibility 2 - Flume with level measurement. Problem: Building a flume to the dimensions of the channel is very expensive. It also requires a costly plant shutdown.

Possibility 3 - Area-velocity flow sensor (contact/in situ).
Problem: Debris and solid particles may cover the sensor and hinder velocity measurement.

Possibility 4 - Transit-time.
Problem: Solid particles reflect the ultrasonic signal from the transmitter, blocking it from the receiver. It also requires a costly plant shutdown.

Solution

Teledyne ISCO LaserFlow
Teledyne ISCO LaserFlow
Teledyne Isco’s LaserFlow Non-Contact Area Velocity Flow Sensor offered an ideal solution to
the site’s metering challenges. The above-water installation of this laser Doppler flow meter is not threatened by the list of potential issues above. Additionally, because it is installed above the water, the installation of the Laser-Flow did not require a plant shutdown.

The LaserFlow remotely measures the level and velocity of the flow in the influent channel. By using an ultrasonic level measurement, the sensor calculates a subsurface point at which to focus an optical laser. The Doppler frequency shift of the returned light is proportionate to the water’s velocity. The LaserFlow is able to measure velocities at up to fifteen points below the water’s surface. This minimizes the effects of turbulence and eliminates the need for manual profiling. By producing exceptionally accurate mean velocity readings and level measurements, the LaserFlow renders some of the most accurate area velocity measurement results in the industry. Additionally, due to the non-contact nature of the LaserFlow sensor, personnel safety is improved and operating costs are greatly reduced.

System Integration and Reporting

The LaserFlow, in conjunction with the Signature Flow Meter, collects level, velocity, and flow parameters that are outputted via 4-20 mA signals and received by the customer’s distributed control system (DCS). These parameters are used in conjunction with others by the DCS to provide comprehensive process control throughout the facility.

The Signature is unique in its ability to verify data integrity as four of its logged data types cannot be altered and are designed to alert the user to any trends or anomalies. This makes the LaserFlow and the Signature excellent choices for creating regulatory compliance reports.

For more information on the Teledyne ISCO LaserFlow, or to discuss your effluent flow challenge, contact Advance Instruments by calling (888) 388-6446 or by visiting https://advanceinstruments.com.

Fuji Electric’s Spool Piece Ultrasonic Flowmeter (FST)


Flow rate inside a pipe is not uniform. A way to correct for this phenomena so that measurement can be accurately obtained is with the use of multiple internal flow sensors. 

By using three sets of sensors, at three parallel paths to each other, the Fuji Electric FST flowmeter can sense both the flow rate at the center of the pipe and the flow rate near the pipe wall. Advanced electronics in the flowmeter housing then averages the flow rates based on Fuji's algorithm to achieve the accuracy of ±0.2% of rate. The Fuji FST delivers accurate measurement regardless of the point of measurement, without being affected by the change in the flow velocity profile.

APPLICATIONS
============
Reduction of water used in plant utilities - Visual depiction of a facility’s water use results in more effective management of water consumption.

Flow monitoring in filtration equipment - Real-time visualization of the filtration capacity allows for the optimization of flow rates, while reductions in pressure loss result in energy savings.

Motor load reduction - Reductions in power consumption are achieved by using an inverter only, instead of a combination of motorized valve and controller to control flow rate.

Flow measurement on two pipes - Optimal ratio of flow control for both pipes.

Liquid level control in tanks - Monitoring the flow rate at inlet and at outlet enables you to manage the liquid level in a tank.

For more information, contact Advance Instruments: